THIẾT BỊ LƯU TRỮ DELL EMC SC7020F ALL FLASH STORAGE ARRAYS

SC5020F SC7020F Chassis Overview Chassis format All-in-one (dual controllers, internal drive bays, networking) with expansion options Rack size 3U 3U Controllers 2 hot-swappable per chassis (active/active) Processors Single Intel Xeon Processor E5-2630 v3, 2.4GHz, 8 cores Dual Intel Xeon Processors, E5-2628 v3 2.5GHz, 8 cores Internal storage capacity 30 x 2.5” drive bays System […]

THIẾT BỊ LƯU TRỮ DELL EMC SC7020F ALL FLASH STORAGE ARRAYS

SC5020FSC7020F
Chassis Overview
Chassis formatAll-in-one (dual controllers, internal drive bays, networking) with expansion options
Rack size3U3U
Controllers2 hot-swappable per chassis (active/active)
ProcessorsSingle Intel Xeon Processor E5-2630 v3, 2.4GHz, 8 coresDual Intel Xeon Processors, E5-2628 v3 2.5GHz, 8 cores
Internal storage capacity30 x 2.5” drive bays
System memory128GB per array (64GB per controller)256GB per array (128GB per controller)
Operating systemDell Storage Center OS (SCOS) 7.2 or greaterDell Storage Center OS (SCOS) 7.2 or greater
Expansion Capacity
Max raw capacity2.16PB per array, more in federated systems4PB per array, more in federated systems
Maximum drive count222 per array (with optional expansion enclosures), more in federated systems606 drives per array, more in federated systems
Supported expansion enclosures12Gb SAS

SC400: 12 x 3.5” bays

SC420: 24 x 2.5” bays

SC460: 60 x 3.5” bays

12Gb SAS

SC400: 12 x 3.5” bays

SC420: 24 x 2.5” bays

SC460: 60 x 3.5” bays

Storage media supportSSD: write-intensive and read-intensive drives (can be mixed in single system), SED SSDs
Network and Expansion I/O
Front-end-network protocolsFC, iSCSI (supports simultaneous multiprotocol)
Max 32Gb FC ports8 per array (SFP+)24 per array (SFP+)
Max 16/8Gb FC ports8 per array (SFP+)24 per array (SFP+)
Max 100Gb iSCSI ports8 per array (SFP28)16 per array (SFP28)
Max 25Gb iSCSI ports8 per array (SFP28)16 per array (SFP28)
Max 10Gb/1Gb iSCSI portsUp to 16 SFP+ (10Gb) or Base-T ports per arrayUp to 32 SFP+ (10Gb) or Base-T ports per array
Management ports2 per array (1Gb BASE-T)
Back-end expansion protocols12Gb SAS
Max back-end expansion ports8 per array24 per array
SC5020FSC7020F
Functional & Performance
Array configurationsAll-flash arrays only
Storage formatNative block (SAN)
Max SAN hosts500500
Max initiator ports10001000
Max LUN size500TB500TB
Max number of LUNs20002000
Max number of snapshots8,19216,384
Max IOPS1,025,0001,200,000
Max IOPS (with latency <1ms)818,0001,050,000
Max IOPS (80% reads, 20% writes)330,000346,000
Max throughput (reads)19,000 MB/s29,000 MB/s
Max throughput (writes)9,500 MB/s14,000 MB/s
Data Optimization
Auto-tiering methodPolicy-based migration based on real-time data usage, customizable 512KB-4MB page size.
Auto-tiering structureUp to 2 SSD tiers (write- and read-intensive SSDs)
Tiering customizationsUser-defined profiles, option to “pin” volumes to any tier
RAID supportRAID 0, 1, 5, 6, RAID 10, and RAID 10 DM (Dual Mirror); any combination of RAID levels can exist in single array
RAID tieringAuto-provisions and dynamically restripes multiple RAID levels on the same tier; no need to pre-allocate RAID groups
Thin provisioningActive by default on all volumes, operates at full performance across all features
Thin snapshotsRecords changes only, snapshots auto-migrate to lower-cost storage
Intelligent deduplication and compressionSelectable option per volume “Deduplication + Compression” and “Compression only” modes available
Data Mobility and Migration
ReplicationHeterogeneous arrays (SC Series any-to-any)

Synchronous/Asynchronous via FC or iSCSI

Target/source relationships may be one-to-many or many-to-one

Supports all SC data services on source and target volumes

Change replication types and topologies on demand

Supports cross-platform replication with PS Series/EqualLogic arrays (either direction)

Volume mobilityLive Migrate (included in base product) enables host-transparent data movement among arrays; see also Federation section
Federated multi-array systemsLive Migrate (included in base product) enables host-transparent movement of volumes among arrays Snapshots maintained/preserved during migration
Thin ImportSpace-efficient, non-disruptive data migration from PS Series (EqualLogic) and MD3 arrays
Thin ClonesClone standalone volumes with zero duplication of data

Clones maintain independent snapshots and replication

Ideal for VDI, test/dev, other applications that require discrete instances of common data

More efficient than dedupe for database copies

Data Protection, Disaster Recovery, Security
Business continuityLive Volume bi-directional auto-failover, auto-repair

Heterogeneous arrays (SC Series any-to-any, except SCv2000)

Continuous operations, disaster recovery, disaster avoidance

Includes third-site (tertiary) replication options with Live Volume Managed Replication

Zero RTO/RPO with customizable site failover SLAs per volume

Does not require identical hardware at each site

VMware Metro Stretch Cluster, VMware Site Recovery Manager support

Thin snapshotsRecords changes only, snapshots auto-migrate to lower-cost storage
Replay ManagerApplication-consistent snapshots in Microsoft, VMware, Oracle environments
Data-at-rest encryptionSupports self-encrypting drives (SEDs)

Full Disk Encryption (FCE) based on AES-256

Drives certified to FIPS 140-2 Level 2

Key Management Server (KMS) options available for FIPS 140-2 Level 1, 2 and 3

External key manager supportGemalto’s SafeNet KeySecure k460, SafeNet KeySecure k250, SafeNet KeySecure k150v Thales EMS 200
Management
Management interfaceBrowser-based (HTML 5)

  • CloudIQ (cloud-based storage monitoring and analytics)
  • Unisphere for SC (single-array element manager, no software installation required)
  • Unisphere Central for SC (multi-array management)

Client application

  • Dell Storage Manager – Advanced multi-array, multi-site and cross-platform (PS Series) management
FederationCreate large multi-array systems under unified management, with seamless workload migration between arrays via included Live Migrate feature. Add arrays non-disruptively, efficiently utilizing their combined capacity and performance. Volume Advisor monitors federated arrays to suggest optimal data placement and load balancing. Volume movement does not impact snapshots or replication data protection. Federate like or unlike arrays, all SC models supported.
Scripting supportMicrosoft PowerShell API

RESTful API

Host OS supportMicrosoft Windows Server, Oracle Solaris, HP-UX, Oracle Linux, IBM AIX, Novell NetWare, SLES, Apple, HPTru64, VMware, Citrix XenServer, RedHat
Third-party application integrationtVMware, Microsoft, IBM, OpenStack, Symantec, CommVault, Foglight, Docker
Coexistence with PS Series arraysReplication in either direction

Day-to-day management from a single interface

Thin import: space-efficient, non-disruptive data migration from PS Series arrays

CertificationsVMware vSphere Metro Storage Cluster, VMware SRM, Veritas Storage Foundations Suite, IBM VIOS Recognized, Oracle Validated Infrastructure (OVI); see Dell Storage Support Matrix for additional certifications and details
Reporting/alertsSupport assist (phone home), remote diagnostics and performance monitoring, automated alerts, reports and notifications, departmental chargeback
Firmware updatesOnline, non-disruptive.

Firmware may be set to download automatically, with option to trigger installation manually if desired.

Workload managementQoS, VVOLs
SC HYBRIDSCV3000 SERIESSC5020
Physical
Rack size3U3U
Height13.33 cm (5.25 inches)13.33 cm (5.25 inches)
Width44.5 cm (17.52 inches)44.5 cm (17.52 inches)
Depth78.5 cm (30.9 inches)78.5 cm (30.9 inches)
Weight at max configuration24.22 kg (53.4 lb)24.22 kg (53.4 lb)
Weight empty15.15 kg (33.4 lb)15.15 kg (33.4 lb)
Rack supportReadyRails II static rails for tool-less mounting in 4-post racks with square or unthreaded round holes, or tooled mounting in 4-post threaded-hole racks
Power
Power/wattage2 hot-swappable power supplies (1378W or 1485W options available, wattage type not interchangeable after point of sale)2 hot-swappable 1485W power supplies
Maximum output power1378 W (1378W supply option) or 1485 W (1485W supply option)1485 W
Maximum input power1584 W (1378W supply option) or 1688 W (1485W supply option)1688 W
Maximum input current16 A (1378W supply option) or 8.8 A (1485W supply option)8.8 A
Maximum inrush current55A for 10 ms or less55A for 10 ms or less
Nominal input voltage operating range100-240 VAC (1378W supply option) or 200-240 VAC (1485W supply option)200-240 VAC
Nominal input frequency50/60 Hz50/60 Hz
Thermal output/heat dissipation (maximum)5,770 BTU per hour (1378W supply option) or 5,760 BTU per hour (1485W supply option)5,760 BTU per hour
Environmental Operating Conditions
Operating temperature50 – 95°F (10 – 35°C)
Non-operating temperature-40 – 149°F (-40 – 65°C)
Operating humidity ranges (non-condensing)10% to 80% with 29°C (84.2°F) maximum dew point
Non-operating humidity (noncondensing)5% to 95% with 33°C (91°F) maximum dew point
Inlet typeNEMA 5-15/CS22.2, n°42
Services, Warranties
ServicesDell ProSupport with deployment and consulting services. Optional ProSupport Plus is available offering proactive and preventative services to improve performance and stability. Dell Optimize is available for additional ongoing strategic counsel and guidance from a highly trained system analyst.
Diagnostics engineIntegrated Dell Remote Access Controller (iDRAC)
System sizingDell EMC Live Optics
Drive warrantyAll SSDs are warrantied for full lifetime wear-out replacement with valid service agreement. SSD warranty covers all formats: SLC, MLC an d TLC